2026-01-14
pureMEMS Saved a Flue Gas Fan
Bearing Fault Detected Before Failure
pureMEMS Saved a Flue Gas Fan
Bearing Fault Detected Before Failure
At Växjö Energi AB, MLT’s wireless pureMEMS sensors predicted an early-stage fault in a critical flue gas fan. In mid-October, our AI software MultiViz detected an abnormal deviation in the vibration pattern. On the very same day, our vibration engineer confirmed the presence of bearing currents, which with high probability would have led to an acute bearing failure. The customer was informed, and four days later, during a scheduled shutdown, the failure was successfully prevented.
Håkan Dahlberg, Maintenance Engineer at Växjö Energi, who followed the process, comments:
“I was initially cautiously skeptical, but was positively surprised and then fully convinced when we opened the bearing housing for inspection.”
Through the right strategy, modern technology, and close technical support, a potentially costly and operationally critical failure, occurring in the middle of the heating season, was instead transformed into a controlled and planned maintenance activity ahead of the next operating season.